4.2 Classification of inspection. The inspection requirements specified herein are classified as
follows:
a. First article inspection (see 4.3).
b. Conformance inspection (see 4.4).
4.3 First article inspection. When a first article is required (see 6.2), it shall be examined for the
defects specified in 4.4.2 and 4.4.3. The presence of any defect shall be cause for rejection of the first
article.
4.4 Conformance inspection. Unless otherwise specified, sampling for inspect ion shall be
performed in accordance with ASQ Z1.4. Unless otherwise specified, the Acceptable Quality Limits
(AQLs) listed in this section shall be used to establish the sample sizes, however, the acceptance number
shall be zero.
4.4.1 Component and material inspection. Components and materials shall be inspected in
accordance with all the requirements of referenced documents unless otherwise excluded, amended,
modified, or qualified in this document or applicable purchase document.
4.4.1.1 Certification. The contractor shall furnish a certificate of compliance for the requirements
specified in 3.2.1 and 3.6.5.
4.4.2 End item visual examination. Each type of component shall be examined for the applicable
defects listed below. The lot size shall be expressed in units of all strong room components. The sample
unit shall be one component. The percentage of samples of each component in relation to the total of all
components sampled shall be proportional to the percentage of that type of component in the lot in
relation to the total of all components in the lot. The inspection level shall be II and the acceptable quality
limit (AQL), expressed in terms of defects per hundred units, shall be 2.5.
Examine
Defect
Material
Not as specified
Wire mesh
Not as specified
Wall and floor
Not as specified, when specified
clamp
Anchor shield missing or not as specified
Components
Missing or not as specified
Identification
Not as specified
marking
Finish
Cleaning, treatment, or painting not as specified
Workmanship
Not an specified
4.4.3 End item dimensional examination. Each type of component shall be examined for
conformance to the dimensions annotated with an asterisk on drawing 13218E8075. Any dimension not
within the specified tolerance shall be classified as a defect. The lot size shall be expressed in units of all
strong room components. The sample unit shall be one component. The percentage of samples of each
component in relation to the total of all components sampled shall be proportional to the percentage of
that type of component in the lot in relation to the total of all components in the lot. The inspection level
shall be S-2 and the AQL, expressed in terms of defects per hundred units, shall be 2.5.